Features for time recording application:
-
Selectable batch or real time operation mode.
-
79 duty codes, duty name defined by PC.
-
Totally 192 alarm schedules (8 schedules per hour) dry contacts output for periodic belling.
-
Could collect data through PC by real time or one by one events or massive block dump.
Main features for access control application:
-
System parameters and personal access map can be downloaded by PC.
-
The personal access map is consisted of card ID, staff number and name, PIN and Time Zone Status, expiry date and Anti-passback.
-
Excellent multiple operation modes :(1) Card only (2)Free access (3) Automatic operation mode by time zones.
-
Individual personal access map can be edited by block range add or delete card in group basis by on-lined PC. Single / block range card number or by directly reading card thru. learning mode.
-
Selectable immediate or batched conditional sorting and then printing out events thru. serial output interface.
-
With complete door release, held monitoring and intruded alarm period and error trials.
-
Supports 8/24/48/64/96 floors lift access control.
-
Full APB (anti-passback), time zone.
-
Could dump all personal map in system by single PC.
|
|
Dimensions
|
118(L) x 75(W) x 17(H)mm
|
|
Weight
|
Net weight:98g ± 5 % Gross weight:204g ± 5 %
|
|
Power input
|
DC 12V±10%
|
| Power consumption |
25mA~60mA(not include power requirement for lock & alarm) |
|
Transmission rate
|
Default 9,600 bps N,8,1(2,400/4,800)(19,200bps/38,400)
|
|
Operating temperature
|
0℃ ~ 70℃
|
|
Operating humidity
|
10%~90%
|
|
Waterproof
|
Yes
|
|
Serial interface
|
RS-485
|
|
Serial output
|
1. For connection with serial printer. 2. To drive DDR (digital door relay) for secure assess control function. 3. To drive 8/24/48/64 relay output modules for lifts access control 4. Bountiful application functions requested by customer
|
|
Events/ Card capacity
by series
|
(1) K Series: 1,000 card capacity,500 events.
(2) L Series: 2,000 card capacity,1,000 events.
(3) M Series: 30,000 card capacity,10,000 events. (4) N Series: 11,000 card capacity,32,000 events.
(5) P Series: 11,000 card capacity,8,000 events. (6) X Series: 32,000 card capacity, 32,000 events.
Other capacity combination requested by order
|
|
Card standard
|
EM 125KHz / Mifare 13.56MHz(ISO 14443A or ISO 14443B)(Depending on order) Wiegand 26/34 bits port for any kind of reader ※ Support customized card.
|
|
External reader
|
With one port for external Wiegand (26/34 bits definable by command) & ABA input(by order)
|
|
|
How to order
PP-36L/M0R5:Mifare(UID) Prox. Controller & Reader 2000 cards, 1000 events, RS-485
PP-36L/M8R5:Mifare Prox. Controller & Reader, Pegasus Key, 2000 cards, 1000 events, RS-485
PP-36L/NR5:EM Prox. Controller & Reader, 2000 cards, 1000 events, RS-485
PP-36L/PR5:Pegasus Prox. Controller & Reader, 2000 cards, 1000 events, RS-485
PP-36X/NR5:EM Prox. Controller & Reader, 32000 users,32000 events, RS-485
PP-36L/N-HEX:EM Prox. Controller & Reader, 2000 cards, 1000 events, Card number:Hexadecimal, 64bit
|